Model
|
ACT40P3
|
|
Type
|
4 Way Cassette
|
|
Room Temperature Display
|
Yes
|
|
Dehumidification
|
Yes
|
|
Sleep Mode
|
Yes
|
|
Advanced Filter System
|
Yes
|
|
Auto-restart
|
Yes
|
|
Remote Control
|
Yes
|
|
Timer
|
Yes
|
|
Moisture Removal (L/h)
|
2.8
|
|
Turbo Mode
|
Yes
|
|
Horizontal/Vertical Air Swing
|
Yes
|
|
Cooling
|
|
|
Btu/h
|
36000
|
|
Input (W)
|
3900
|
|
Rated Current (A)
|
7.6
|
|
EER (W/W)
|
2.71
|
|
Heating
|
|
|
Btu/h
|
40000
|
|
Input (W)
|
3990
|
|
Rated Current (A)
|
7.8
|
|
COP (W/W)
|
2.94
|
|
Outdoor Unit
|
|
|
Type
|
SCROLL
|
|
Brand
|
SANYO
|
|
Dimension (mm)
|
990x966x354
|
|
Weight N/G (kg)
|
94/100
|
|
Outdoor Noise Level (dBA)
|
60
|
|
Indoor Unit
|
|
|
Indoor Air Flow (m3/h)
|
1648/1501/1326
|
|
Indoor Noise Level (dBA)
|
50/45/43
|
|
Dimensions (mm)
|
Body(840x840x300) Panel(950x950x55)
|
|
Weight (kg)
|
Body(30/36) Panel(6/9)
|
|
Technical Information
|
|
|
Energy Class
|
|
|
Max Input consumption (W)
|
5300
|
|
Max Current (A)
|
10
|
|
Starting Current (A)
|
43
|
|
Ambient Temp: Cooling/Heating (ºC)
|
21~43/-5~24
|
|
Application Area (m2)
|
42-70
|
|
Power Supply (V / Hz / Ph)
|
220-240V / 50Hz / 1Ph
|
|
Refrigerant Type
|
R22
|
|
Refrigerant Piping Liquid (mm/inch)
|
φ9.5 (3/8")
|
|
Refrigerant Piping Gas (mm/inch)
|
φ19 (3/4")
|
|
Max. Refrigerant Pipe Lenght (m)
|
50
|
|
Max. Difference in Level (m)
|
20
|
|
Container Loading Quantity 20/40/40HC
|
50/106/108
|
|
Origin
|
China
|
|